loading

Professional manufacturer of tile grout and adhesives with 27 years experience

What toilet waterproof construction acceptance criteria?

What toilet waterproof construction acceptance criteria? Small small make up take you to discuss together. 1, after doing waterproof construction process after check the toilet waterproof construction before each process ( Basic level processing, leveling layer construction, hole cleaning and sealing, filling sealing, detail additional layer, etc. ) Complete, confirmed by the supervision engineer to check and make inspection records, before being construction of next working procedure. 2, bathroom waterproof coating after the acceptance of each time the waterproof layer brushing is completed, after confirmed by the supervision engineer inspection requirements, may under the waterproof layer coating operation again. 3, waterproof layer after coating is dry need acceptance after fuzhou waterproof coating in dry, to improve the quality of the waterproof layer of check and acceptance, check whether content including waterproof layer coating, thickness is uniform and closed whether strict, thickness of whether to meet the design requirements, Biopsy samples) , without the drum surface, such as crack, become warped edge defects. By party a and supervision engineer joint inspection qualified rear can be closed water test. 4, bathroom waterproof closed water test the waterproof layer must be closed water test, the test of time not less than 24 hours, at the bottom of the floor, pipes and other surrounding areas such as the wall edge part shall not appear ooze water, wet phenomenon. With party a and supervision engineer to check the acceptance inspection and concealment acceptance records, can enter into next working procedure construction of waterproof layer. 5, after the completion of the decoration waterproof acceptance fine decoration in toilet waterproofing coating protective layer, after the completion of the construction should be professional plumbing pipes laid of qualified and experienced, can cushion the construction, working procedure in the process of transition, should closely cooperate with equipment and foundation construction company. 6, secondary closed water test after completion of the ground surface, fine decoration toilet should be closed water test for the second time, closed water time not less than 24 hours, during which the corners observation beneath the floor, wall, no leakage, no wetting phenomenon in areas such as the pipeline surrounding for qualified, at the same time fill in closed water inspection record and waterproof construction acceptance according to procedures.

GET IN TOUCH WITH Us
recommended articles
Knowledge APPLICATION NEWS
Sealant Composition and Function

Sealants are commonly used in construction and home improvement projects to fill gaps and cracks, providing a watertight and airtight seal.
Every successful project needs purpose-built solutions to ensure efficiency, effectiveness, and overall success.
Contact Adhesive Safety Guidelines: What to Follow

Contact adhesive is a versatile and widely used adhesive that is commonly used for bonding materials such as wood, metal, and plastic.




What is Contact Adhesive?

Contact adhesive is a type of adhesive that is widely used for flexible bonding applications.
In today's highly competitive market, businesses are constantly looking for ways to bring innovative products to market faster and more efficiently.
no data

Contact Us

Whatsapp : +86 13924533378
Wechat : +86 13924533378
Tel : +86 731 89870169
E-mail : sales@kastarsealant.com
Address: No.1, ShunJing Road, Songxia Industrial Park, SongGang Town, Foshan, China

Better Touch Better Business

Contact Sales at Kastar.

Call Us

+86 13924533378

Copyright © 2025 Kastar adhesive Co.,Ltd. | Sitemap
Customer service
detect